<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-18 18-21-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 70 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.3 kHz 81 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 65 kHz 19089 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,3 dBr 2,80 dBr 3,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Royal Liverpool Philharmonic Orchestra "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 65 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2024/12/18 18.20.43 Total samples: 19089 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 3,7 dBr MIN: 1,3 dBr AVE: 2,80 dBr % above 12,2 dBr: 0,0 Last value: 2,5 dBr (2024/12/18 18.20.43) 18.06 18.08 18.10 18.12 18.14 18.16 18.18 18.20 0 50 100 Dev. MAX [kHz] -1 0 1 2 3 4 Pm [dBr]